Product
Inverter
HDSX Three Phase Inverter&Three Phase Solar Inverter(4KVA-200KVA)
Keywords: solar household system, solar energy system, solar micro-grid power station
Feature:
◆ Pure sine wave output.
◇ Low DC voltage, saving system cost.
◆ Built-in PWM or MPPT charge controller.
◇ AC charge current 0-45A adjustable.
◆ Wide LCD screen, clearly and precisely shows icon data.
◇ 100% imbalance loading design, 3 times peak power.
◆ Setting different working modes based on variable usage requirements.
◆ Various communication ports and Remote monitoring RS485/APP(WIFI/GPRS) (Optional)
Specification | ||||||||||
Model: HDSX/HDSX-T | 32248/96/192 | 48248/96/192 | 56248/96/192 | 64248/96/192 | 80248/96/192 | 10348/96/192 | 12348/96/192 | 16396/192 | 20396/192 | 24396/192 |
Rated Power | 4KVA/3.2KW | 6KVA/4.8KW | 7KVA/5.6KW | 8KVA/6.4KW | 10KVA/8KW | 12.5KVA/10KW | 15KVA/12KW | 20KVA/16KW | 25KVA/20KW | 30KVA/24KW |
Peak Power(20ms) | 9.6KVA | 14.4KVA | 16.8KVA | 19.2KVA | 24KVA | 30KVA | 36KVA | 48KVA | 60KVA | 72KVA |
Start Motor | 3HP | 4HP | 4HP | 4HP | 5HP | 6HP | 7HP | 10HP | 10HP | 15HP |
Battery Voltage | 48/96/192VDC | 96/192VDC | ||||||||
Built-in solar controller charging current (Optional) | PWM: 10A-60A(48V System); 50A/100A(96V System); 50A(192V System) | PWM: 50A/100A(96V System); 50A/100A(192V System) | ||||||||
Size(L*W*Hmm) | 565*300*775 | 725*365*1010 | ||||||||
Packing Size(L*W*Hmm) | 625*360*895 | 785*425*1135 | ||||||||
N.W.(kg) | 65 | 73 | 75 | 80 | 112 | 122 | 134 | 160 | 176 | 189 |
G.W.(kg)(Wooden Packing) | 78 | 86 | 88 | 93 | 136 | 146 | 158 | 184 | 200 | 213 |
Installation Method | Tower | |||||||||
技术规格 | |||||||||||
Model: HDSX | 323192 | 403192 | 483384 | 643384 | 803384 | 963384 | 1003384 | 1203384 | 1283384 | 1503384 | 1603384 |
Rated Power | 40KVA/32KW | 50KVA/40KW | 60KVA/48KW | 80KVA/64KW | 100KVA/80KW | 120KVA/96KW | 125KVA/100KW | 150KVA/120KW | 160KVA/128KW | 190KVA/150KW | 200KVA/160KW |
Peak Power(20ms) | 96KVA | 120KVA | 144KVA | 192KVA | 240KVA | 288KVA | 300KVA | 360KVA | 384KVA | 450KVA | 480KVA |
Start Motor | 15HP | 20HP | 25HP | 30HP | 40HP | 50HP | 50HP | 60HP | 60HP | 80HP | 80HP |
Battery Voltage | 192VDC | 384VDC | |||||||||
Built-in solar controller charging current (Optional) | PWM: 100A-200A(192V&384V System) | PWM: 100A-200A / MPPT: 50A/100A | |||||||||
Size(L*W*Hmm) | 720*575*1275 | 875*720*1380 | 1123*900*1605 | ||||||||
Packing Size(L*W*Hmm) | 785*640*1400 | 980*825*1560 | 1185*960*1750 | ||||||||
N.W.(kg) | 240 | 260 | 290 | 308 | 512 | 542 | 552 | 612 | 642 | 705 | 755 |
G.W.(kg)(Wooden Packing) | 273 | 293 | 323 | 341 | 552 | 582 | 592 | 652 | 692 | 755 | 805 |
Installation Method | Tower | ||||||||||
Parameter | ||
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |
AC Input Frequency Range | 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) | |
Max AC charging current | 0-45A(Depending on the model) | |
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |
Phase | 3/N/PE | |
Output | Efficiency(Battery Mode) | ≥85% |
Output Voltage(Battery Mode) | 380Vac/400Vac±2%(customized 190Vac/200Vac) | |
Output Frequency(Battery Mode) | 50/60Hz ±1% | |
Output Wave(Battery Mode) | Pure Sine Wave | |
Output waveform distortion | Linear load≤3% | |
Efficiency(AC Mode) | >99% | |
Output Voltage(AC Mode) | Conforming to AC input | |
Output Frequency(AC Mode) | Conforming to AC input | |
No load loss(Battery Mode) | ≤2.5% rated power(4KVA-30KVA models);≤1% rated power(40KVA-200KVA models) | |
No load loss(AC Mode) | ≤2%rated power( charger does not work in AC mode) | |
No load loss(Energy saving Mode) | ≤10W | |
Phase | 3/N/PE | |
Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements | |
Protection | Battery undervoltage alarm | 11V(Single battery voltage) |
Battery undervoltage protection | 10.5V(Single battery voltage) | |
Battery overvoltage alarm | 15V(Single battery voltage) | |
Battery overvoltage protection | 17V(Single battery voltage) | |
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | |
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |
Temperature protection | >90°C(Shut down output) | |
Alarm | A | Normal working condition, buzzer has no alarm sound |
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |
Inside Solar controller | Charging Mode | MPPT or PWM |
Charging current | PWM: 10A/20A/30A/40A/50A/60A(48V System); 50A/100A/150A/200A(96V/192V/384V System) | |
PV Input Voltage Range | PWM: 60V-88V(48V System); 120V-176V(96V System); 240V-352V(192V System); 480V-704V(384V System) | |
Max PV Input Voltage(Voc) | PWM: 100V(48V System); 200V(96V System); 400V(192V System); 750V(384V System) | |
PV Array Maximum Power | 48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A) | |
Standby loss | ≤3W | |
Maximum conversion efficiency | >95% | |
Working Mode | Battery First/AC First/Saving Energy Mode | |
Transfer Time | ≤4ms | |
Display | LCD | |
Thermal method | Forced air cooling | |
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | |
Environment | Operating temperature | -10℃~40℃ |
Storage temperature | -15℃~60℃ | |
Noise | 2000m(More than derating) | |
Elevation | ≤65dB | |
Humidity | 0%~95% ,No condensation | |
Product Message