Inverter

Product

LF Inverter/Solar Inverter (1KW)

LF Inverter/Solar Inverter (1KW)

Keywords: solar household system, solar energy system, solar micro-grid power station

+
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

Feature:

◆ With Toroidal low-loss transformer, high-efficiency inverter conversion, pure sine wave output. 

◆ Intelligent LCD display. 

◆ Provide adjustable working modes: mains priority, inverter priority. 

◆ Optional built-in MPPT solar controller to achieve     high-efficiency charging. 

◆ Support diesel and gasoline generators, suitable for various grid power. 

◆ Support RS485 communication /mobile APP (optional). 

 

Specification
Model: LF/LF-T10212/24
Rated Power1000W
Battery Voltage12/24VDC
Size(L*W*Hmm)333x253x126
Packing Size(L*W*Hmm)423x318x205
N.W.(kg)9
G.W.(kg)10
Installation MethodWall-Mounted
Parameter
InputDC Input Voltage Range10.5-15VDC(Single battery voltage)
AC Input Voltage Range68VAC~133VAC(105VAC)/73VAC~138VAC(110VAC)/78VAC~143VAC(115VAC)/83VAC~148VAC(120VAC)/
145VAC~275VAC(220VAC)/155VAC~285VAC(230VAC)/165VAC~295VAC(240VAC)
AC Input Frequency Range45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current0~15A(Depends on model)
AC charging methodThree-stage (constant current, constant voltage, floating charge)
OutputEfficiency(Battery Mode)≥85%
Output Voltage(Battery Mode)AC105V~120V model: 105VAC±2%/110VAC±2%/115VAC±2%/120VAC±2%(can be set)
AC220V~240V model: 220VAC±2%/230VAC±2%/240VAC±2%(can be set)
Output Frequency(Battery Mode)50/60Hz±1%(can be set)
Output Wave(Battery Mode)Pure Sine Wave
Efficiency(AC Mode)≥99%
Output Voltage(AC Mode)AC 105V~120V model: 105VAC±10%/110VAC±10%/115VAC±10%/120VAC±10%(can be set)
AC 220V~240V model: 220VAC±10%/230VAC±10%/240VAC10%(can be set)
Output Frequency(AC Mode)Follow input
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode)≤0.8% rated power
No load loss(AC Mode)≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery
Type
Custom batteryCharging and discharging parameters of different types of batteries can be set through the operationpanel by oneself
Insidc
Solar
controller
(Optional)
Charging ModeMPPT
Charging current30A/40A/60A
PV Array Maximum Power12V system: 420W(30A)/560W(40A)/840W(60A);
24V system: 840W(30A)/1120W(40A)/1680W(60A)
Max PV Input Voltage (Voc)
(At the lowest temperature)
120VDC
MPPT tracking range15V-80V
Standby loss≤3W
Maximum conversion efficiency>95%
ProtectionBattery lowvoltage alarmFactory default: Pb:11V/Single battery voltage;LI* : 10% of the battery capacity
Battery lowvoltage protectionFactory default: Pb:10.5V/Single battery voltage ; LI* :5% of the battery capacity
Battery overvoltage alarmFactory default: Pb:15.5V/Single battery voltage;LI* : following BMS instruction
Battery overvoltage protectionFactory default: Pb:17V/Single battery voltage;LI* : following BMS instruction
Battery overvoltage recovery voltageFactory default: Pb:14.5V/Single battery voltage;LI*: following BMS instruction
Overload power protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection>90°C(Shut down output)
AlarmANormal working condition, buzzer has no alarm sound
BBuzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
CWhen the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Working ModeBattery First/AC First/Saving Energy Mode
Transfer Time≤4ms
DisplayLCD
Thermal methodCooling fan in intelligent control
CommunicationRS485/APP(WIFI/GPRS data collector)
EnvironmentOperating temperature-10℃~40℃
Storage temperature-15℃~60℃
Noise≤55dB
Elevation2000m(More than derating)
Humidity0%~95% ,No condensation

Note: All specifications are subject to change without prior notice